Hydrogen Embrittlement


A premature fatigue of metal and ceramic caused by the presence of free hydrogen.

This is a major cause of ceramic breakage in hot water seal applications and premature bearing fatigue, if moisture penetrates into the bearing case.

The free hydrogen gas is created when the water or moisture separates into atomic hydrogen and oxygen.