Internal Recirculation

INTERNAL RECIRCULATION I020

A loss of efficiency caused by liquid flowing through wear rings in closed impeller designs or the impeller to volute clearances in open impeller designs.

In some centrifugal pump designs (Duriron is an example) the clearance is between the impeller and the backplate.

Category

Posted

  • On February 16, 2018